Equipment

QM-980+(980nm+1470nm)

980nm + 1470nm Diode Laser

Diode Laser · Spider vein removal; Body Slimming

980+1470nm diode laser lipolysis, precisely locates excess fat, directly hits the target tissue fat cells, and rapidly dissolves and liquefies. The instrument mainly acts on deep fat and superficial fat, and transfers the energy directly to the fat cells for uniform heating. During the heating process, the connective tissue and fat cell structure can be changed by controlling the heat, and the adipose tissue has a photothermal effect (so that the fat isdissolved). And the photodynamic effect (separating the fat cells from the normal tissue) decomposes the fat cells to make them evenly liquefied, and the fat liquid is excreted through the ultra-fine positioning needle, which fundamentally reduces the number of fat cells, effectively avoids postoperative rebound.
1470nm laser has high cutting efficiency and can be transmitted through optical fiber. It can be absorbed by both hemoglobin and cell water. The heat can be concentrated in small tissues, rapidly vaporize and decompose tissues, with less heat damage, and has the advantages of coagulation and hemostasis. It is suitable for minimally invasive surgery such as tumor resection, surgery, prostatectomy, varicose veins, etc.

Application

980nm + 1470nm is very effective at targeting stubborn pockets of fat in all areas of the body including:

  • The buttocks
  • Hips and thighs
  • Abdomen and stomach area
  • Upper arms
  • Breast and chest
  • Neck and chin
  • Knees
Advantages
  • The patient feels much less pain as compared to other procedure
  • There is no need for hospitalization for the procedure. The patient can get discharged on the same day
  • In comparison to traditional surgical options, laser surgery is much safer
  • Since the blood vessels in the anal region are sealed off by the laser, minimum bleeding is caused during the procedure
  • Chances of any other medical complication arising are minimum
  • The surgeon has many options for effective utilization of the laser beam, thus improving the chances of success through the surgery
  • The surgeon's task is much less complicated and risky
  • Aids in the fast healing of the wound
  • Since general anesthesia isn't needed for the procedure, the recovery is much faster

Technical Parameters

Laser type

Diode Laser Gallium-Aluminum-Arsenide GaAlAs

Wavelength

980nm+1470nm

Power

1-30W for 980nm, 1-30W for 1470nm

Working Modes

CW, PW

Aiming Beam

Adjustable Red indicator light 650nm

Fiber type

Radial fiber

Fiber diameter

600 Fiber

Fiber connector

SMA-905 International standard interface,

special quartz optical fiber laser transmission

Pulse

0.00s-1.00s

Delay

0.00s-1.00s

Voltage

100-240V, 50/60HZ

Size

51*47*46cm

Gross Weight

20kg

980nm + 1470nm Diode Laser Machine FAQ

▶ Do you offer training and clinical support after purchase?

Absolutely. We provide complete training (online), user manuals, and clinical protocols to ensure safe operation of the spider vein removal machine. Ongoing technical and marketing support is also available for distributors and clinics.

▶ What is the typical return on investment (ROI) for clinics using this laser device?

Because the spider vein removal machine has no consumables, low operating costs, short treatment times, and high patient demand for spider vein removal, clinics typically see a return on investment within a few weeks. We also provide marketing materials to our partners to help them acquire customers.

▶ If you're considering purchasing a Vascular treatment machine, you should be aware of the following advantages:

Wavelength Precision –The 980nm diode laser offers optimal absorption by hemoglobin, making it ideal for precise and efficient laser treatment for spider veins with minimal damage to surrounding tissue.

Stability and Output Power –Look for equipment with stable laser output and adjustable parameters to ensure safe and consistent results across different skin types.

Ergonomic and User-Friendly Design –A compact, intuitive system saves space in your clinic and shortens the learning curve for practitioners. Features like a touchscreen interface and preset protocols are added benefits. Plug-and-Play technology, no installation required after shipping

Profitability & ROI –A good spider vein removal device should offer a strong return on investment by delivering visible results, short treatment times, and no consumables.

Configuration notice: Specifications, accessories, interface options and permitted uses vary by destination market and confirmed configuration. The Proforma Invoice, configuration sheet and model-specific documents supplied before payment take precedence.

Treatments

Build your treatment menu.

Final configuration and supplied accessories are confirmed in the quotation.

Specifications

QM-980+(980nm+1470nm) · Overview

Final configuration and supplied accessories are confirmed in the quotation.

QM-980+(980nm+1470nm)
Aiming Beam
Adjustable Red indicator light 650nm
Delay
0.00s-1.00s
Fiber connector
SMA-905 International standard interface, special quartz optical fiber laser transmission
Fiber diameter
600 Fiber
Fiber type
Radial fiber
Gross Weight
20kg
Laser type
Diode Laser Gallium-Aluminum-Arsenide GaAlAs
Power
1-30W for 980nm, 1-30W for 1470nm
Pulse
0.00s-1.00s
Size
51*47*46cm
Voltage
100-240V, 50/60HZ
Wavelength
980nm+1470nm
Working Modes
CW, PW
Request a Quote

Documents & support

Documents & support

Review available model documents and discuss training, warranty and spare-part arrangements before ordering.

ZENLASE

Let’s find the right configuration.

Tell us your application and destination country. Receive a model-specific quotation or discuss your plans on WhatsApp.

WhatsApp

Your contact details are used to respond to this enquiry.

QM-980+(980nm+1470nm)Request a QuoteWhatsApp
980nm + 1470nm Diode Laser (QM-980+(980nm+1470nm)) | ZENLASE