Equipment

QM-10600B

CO₂ Laser System

Co2 Fractional Laser · Scar Removal; Pigmentation Removal; Female Health

Portable CO2 Laser Machine

The Portable fractional CO2 laser is primarily used for anti-aging treatments and can be used to treat a variety of challenging skin imperfections, such as wrinkles, fine lines, photodamage, uneven skin tone, skin laxity, as well as scars and skin tags. The system combines high-intensity CO2 laser technology with adjustable treatment modes and multi-level fraction density adjustment, providing personalized, precisely controlled treatment options for dermatology and cosmetic surgery.

It can be used for the removal of acne, acne scars, freckles, and scars, as well as for anti-aging and, primarily, scar revision. Seven adjustable treatment patterns allow the physician to precisely target specific areas and control treatment parameters, as well as thermal control through pulse duration and energy delivery mode. This versatility enhances treatment precision and effectiveness while minimizing unnecessary tissue damage.

CO2 laser Applications

Applications

This portable CO2 laser offers a compact yet powerful solution for skin resurfacing and dermatological treatments. It utilizes fractional CO2 laser technology to create controlled, minimally invasive procedures, stimulating the body's natural healing process and collagen regeneration to effectively treat acne scars, fine lines, wrinkles, enlarged pores, skin laxity, and hyperpigmentation.

  • Skin renewing and resurfacing
  • Wrinkle removal, skin tightening
  • Acne and scar removal, melasma removal
  • Smooth scars like burn, surgery, traumatic, and stretch marks
  • Remove intractable chloasmas and pigmentation
  • Sun damage recovery

This lightweight system is ideal for both in-clinic and mobile aesthetic use, offering precise and customizable settings for a variety of skin types and treatment areas, including the face, neck, upper chest, and even sensitive areas. Its portability makes it ideal for small clinics, dermatology clinics, and professionals providing on-site skin care services.

How does Co2 Fractional Laser work?

Working Principle

Portable CO2 lasers utilize a 10.6μm wavelength, which is highly absorbed by water in skin tissue. Laser energy is transmitted through an articulated arm, supporting stable beam transmission and high energy density, making them suitable for precise clinical manipulation.

Because CO2 lasers operate in the invisible infrared wavelength range, Protable CO2 lasers are often equipped with a visible red indicator light to help locate the treatment area. When the laser is applied to the skin through a focusing lens, the light energy is rapidly converted into heat, vaporizing or thermally coagulating the target tissue.

In fractional mode, the laser light is dispersed into multiple tiny beams, creating regularly arranged micro-treatment zones while leaving the surrounding skin untreated. This fractionated treatment approach effectively stimulates collagen remodeling, improves skin texture, and improves scarring while significantly minimizing overall damage. It accelerates the repair of surrounding normal tissue, thereby shortening recovery time and improving treatment safety.

Fractional Scanner

Designed for efficient and precise tissue treatment, it is particularly suitable for improving skin texture and pigmentation.

This handheld scanner features a built-in microprocessor control system and supports carbon-free ablation, effectively treating large areas. It is widely used in dermatology, medical aesthetics, and other fields. It offers a variety of scan patterns, including square, rectangular, triangular, hexagonal, circular, elliptical, and linear modes, with a maximum scanning range of approximately 20mm x 20mm.

Protable CO2 laser Ultra-PulseCO2 laser Vaginal Mode

Ultra-Pulse

This Portable CO2 laser system provides precise cutting and coagulation capabilities, making it an ideal tool for various surgical procedures.

In"Cutting"mode, the treatment head delivers ultra-short pulses with high peak power, instantly vaporizing tissue for efficient ablation. In"Coagulation"mode, longer pulses combined with medium-to-low power outputs promote vasoconstriction and tissue coagulation through thermal effects. This synergistic pulse sequence enables more precise cutting or resection, effectively controls intraoperative bleeding, and helps shorten the patient's postoperative recovery time. The treatment head is equipped with a fixed-focus handpiece and a variety of spot sizes to choose from, further improving the precision and operational adaptability of soft tissue surgery.

Vaginal Mode

1.Tighten vagina - Fast tightening, lasting constriction, tightness to improve 60%;

2.Clean the vagina - Deep anti-aging, young level to improve 80%;

3.Moist vagina - lmproving secretion, moisture level to improve 80%;

lmported excellent 7 articular optical-arm, easy operated and greatly reduces the energyloss;

Advantages of Portable CO2 Laser machine

  • 3 in 1 system (Fractional + VRL + CO2) , easy and convenient for operation, high returninvestment
  • appropriate fractional probe-CPG (Central Pattern Generator), big and even energy output,deep penetration;
  • 6 scan modes: Sequence, Random, Maximum distance, Equidistance and fastshot;
  • 7 scan shapes, scan size 0.1*0.1mm-20*20mm
  • Ultra-quiet pump used, lower noise but larger water flow;
  • Taiwan Mean Well power supply, ensures stable and sufficient power supply during treatment, long service life.
  • Safe treatment. designed for trained professional operation, the VRL system has been tested by hundreds of women worldwide, and the ideal wavelength is absorbed by mucous membrane microns, avoiding any thermal damage to deep tissues or organs.
  • Fast treatment. Each treatment takes less than 30 minutes, and 1-3 treatments can completely solve skin and vaginal problems
  • Effective treatment. It is effective for all women with loose vaginas, can effectively prevent gynecological inflammation, and is also effective for all people with skin problems such as acne scars, stretch marks, and large pores
  • designed for improved treatment comfort treatment: anesthesia requirements depend on the treatment protocol and local practice is required, and you can enter/exit the VRL procedure.

Before&After

Technical Parameters

Wavelength10600nm
Laser apparatusSealed off laser device simulated by direct current
Optical beam qualityTEM00
Output power
1-60W
Spot size0.02~0.05mm²
Aiming beamRed semiconductor laser (635nm, less than 5mw)
Beam transport deviceArticulated arm with 7-joint and balance weight
Working mode
Continuous operation
Scan modeNormal, Midsplit, Random
Scan scopeMax 20mmx20mm
Scan graphics
Circle, triangle, square, rectangle, hexagon, ellipse, line
It can also be freely deformed based on the above
Scan speedMore than 10m/s
Distance0.1-2.6mm
Cooling systemAir circulation
Power220V / 110V

Portable CO2 Laser FAQs

▶ Who needs fractional CO2 laser treatment?

Fractional CO2 laser treatment is ideal for those who want to minimize the appearance of acne scars, fine lines, pigmentation, sun damage, warts, and a lot of other skin conditions. Dermatologists also recommend fractional CO2 laser treatments to those who suffer from non-responsive skin.

▶ How to use a fractional CO2 laser machine?

Patient Counseling and Selection:

Medical History: Conduct a comprehensive consultation. Review the patient's medical history, including skin type (Fitzpatrick skin grades I-IV are generally preferred), current medications (particularly isotretinoin, which must be discontinued for at least 6-12 months), history of herpes labialis (herpes simplex virus infection), keloid scarring, and immune status.

Expectations: Discuss the actual efficacy, potential risks, recovery period, and the number of treatments required (usually 1-3 sessions spaced 4-6 weeks apart). Informed Consent: After explaining all risks and benefits, obtain written informed consent.

Pretreatment Preparation (Weeks Before Treatment):

Skin Care Regimen: Patients may take a topical retinoid (e.g., tretinoin) and/or hydroquinone 2-4 weeks before treatment to prepare the skin and reduce the risk of post-inflammatory hyperpigmentation (PIH). Antiviral Prophylaxis: For patients with a history of cold sores, oral antiviral medication (e.g., valacyclovir) is recommended starting 2 days prior to treatment and continuing for several days.

On the Day of Treatment:

Pre-treatment Photographs: Standard, high-quality photographs of the treatment area should be taken.

Skin Cleansing: The patient's skin must be thoroughly cleansed with a gentle, non-greasy cleanser, removing all makeup, sunscreen, and oil.

Anesthesia:

Local Anesthesia: Prior to the procedure, a strong local anesthetic cream (e.g., lidocaine/tetracaine) is applied to the treatment area and covered with an occlusive dressing for 60-90 minutes. This is crucial for patient comfort. Other Options: For more aggressive treatments or full-face procedures, nerve blocks or oral sedatives may be used clinically.

▶ Are fractional CO2 laser results permanent?

The effects of fractionated CO2 laser treatment aren't permanent, but they can be long-lasting. By stimulating collagen regeneration, it can significantly improve wrinkles, scars, and other skin problems. This tissue regeneration typically lasts for several years. However, since it can't prevent future natural aging, the longevity of these results depends heavily on strict post-surgery sun protection and maintenance.

▶ How long does it take to see results from treatment?

Initial results can be seen in 1-2 weeks, but significant results may take 1-3 months to see, depending on the customer's skin condition.

Configuration notice: Specifications, accessories, interface options and permitted uses vary by destination market and confirmed configuration. The Proforma Invoice, configuration sheet and model-specific documents supplied before payment take precedence.

Treatments

Build your treatment menu.

Final configuration and supplied accessories are confirmed in the quotation.

Specifications

QM-10600B · Overview

Final configuration and supplied accessories are confirmed in the quotation.

QM-10600B
Aiming beam
Red semiconductor laser (635nm, less than 5mw)
Beam transport device
Articulated arm with 7-joint and balance weight
Cooling system
Air circulation
Distance
0.1-2.6mm
Laser apparatus
Sealed off laser device simulated by direct current
Optical beam quality
TEM00
Output power
1-60W
Power
220V / 110V
Scan graphics
Circle, triangle, square, rectangle, hexagon, ellipse, line It can also be freely deformed based on the above
Scan mode
Normal, Midsplit, Random
Scan scope
Max 20mmx20mm
Scan speed
More than 10m/s
Spot size
0.02~0.05mm²
Wavelength
10600nm
Working mode
Continuous operation
Request a Quote

Documents & support

Documents & support

Review available model documents and discuss training, warranty and spare-part arrangements before ordering.

FAQ

Questions before you order

Which configuration fits my needs?+

Share your application, destination country and planned service menu. We will help compare the available model options.

What is included in the quotation?+

Confirm the exact model, handpieces, accessories, documentation and delivery arrangements in the written quotation.

ZENLASE

Let’s find the right configuration.

Tell us your application and destination country. Receive a model-specific quotation or discuss your plans on WhatsApp.

WhatsApp

Your contact details are used to respond to this enquiry.